C15811-50
BA Series 紧凑的模块化放大器
BAS
BA
BL
BA50
BA75
BA100
BA10-x 5 A cont., 10 A peak servo amplifier/power supply
BA20-x 10 A cont., 20 A peak servo amplifier/power supply
BA30-320-S 15 A cont., 30 A peak servo amplifier/power supply, w/shunt regulator
BA50-320-S 25 A cont., 50 A peak servo amplifier/power supply, w/shunt regulator 230 VAC, 1 phase input
BA75-320-S 37 A cont., 75 A peak servo amplifier/power supply, w/shunt regulator 230 VAC, 3 phase input
BA100-320-S 50 A cont., 100 A peak servo amplifier/power supply, w/shunt regulator 230 VAC, 3 phase input
BA Series Amplifier Options
-S Add shunt resistor network for BA10 or BA20 (standard on the BA30, BA50, BA75, BA100) EX: BA20-160-S
Bus Voltage
-40* 40 VDC bus; 28 VAC input required (use TV0.3-28)
-80* 80 VDC bus; 56 VAC input required (use TV0.3-56)
-160 160 VDC bus; 100-115 VAC input, direct line operation (for 80 VDC bus use TV0.3-56 transformer)
-320 320 VDC bus; 230 VAC input, direct line operation (includes shunt regulator)
Note: Requires transformer such as TV0.3-28 OR TV0.3-56 for 56VAC input voltage.
BA Accessories
TV0.3-28 0.3 kVA autotransformer; 28 or 56 VAC out for 40 or 80 VDC bus, 115/230 VAC, 50/60 Hz input
TV0.3-56 0.3 kVA autotransformer; 56 or 115 VAC out for 80 or 160 VDC bus, 115/230 VAC, 50/60 Hz input
TV1.5 1.5 kVA isolation transformer, 115/230 VAC input; 28, 43, 56, 70, 115 VAC output
TV2.5 2.5 kVA isolation transformer, 115/230 VAC input; 28, 43, 56, 70, 115 VAC output
TV5 5 kVA isolation transformer, 115/230 VAC input; 28, 43, 56, 70, 115 VAC output
TB Screw terminal block for BA DB25 control connector
LF AC line filter, general noise supression (not for CE Compliance)
UFM AC line filter module (required for BA amplifiers to meet CE compliance)
Motor Feedback Cables (Brushless)
C15291-50 Feedback cable, BM series brushless motor to controller, 15 ft., MS, DB25
PFC-15 Feedback cable, BM series brushless motor to controller, 15 ft., MS, FL
C18391-50 Feedback cable, BMS series slotless motor to controller, 15 ft., DB25, DB25
Motor Power Cables (Brushless)
C15801-50 Motor power cable, BA amplifier to: BM75, BM130, BM200, BM250, 15 ft.
C15811-50 Motor power cable, BA amplifier to: BM500, BM800, BM1400, 15 ft.
PMC2-15 Motor power cable, BA amplifier to: BM2000, BM3400, BM4500, 15 ft.
C17891-50 Motor power cable, BA amplifier to BMS series motors, 15 ft.
Motor Feedback & Power Cables (DC brush-type)
BADC-MSO-15 Integral cable, BAS to 1017, 1035, 1050, 1075, 1135, 1210, 1410 DC motor
with MSO1, 15 ft, MS -> DB25, FL
BAMS-O-15 Integral cable, BAS to 1580, 1960 DC motor with MSO1, 15 ft, MS -> DB25, FL
Control Cables
BAC2-3 Amplifier cable, BA amplifier to control for brushless series motors, 3 ft.
BAC6-3 Amplifier cable, BA amplifier to control for DC brush series motors, 3 ft.
Rev 1.0a February 21, 1995
Rev 1.1 July 27, 1995
Rev 1.1a November 1995
Rev 1.2 May 23, 1996
Rev 1.3 May 15, 1997
Rev 1.3a September 30,1997
Rev 1.4 February 11, 1998
Rev 1.4a March 8, 2000
Rev 1.5 December 13, 2000
Rev 1.5a February 13, 2001
Rev 1.6 February 5, 2002
BA10-40
BA20-40
BA30-40
BA10-80
BA20-80
BA30-80
BA10-160
BA20-160
BA30-160
BA10-320
BA20-320
BA30-320
BA10-40-S
BA20-40-S
BA30-40-S
BA10-80-S
BA20-80-S
BA30-80-S
BA10-160-S
BA20-160-S
BA30-160-S
BA10-320-S
BA20-320-S
BA30-320-S
附件
TV0.3-28 0.3 kVA autotransformer; 28 or 56 VAC out for 40 or 80 VDC bus, 115/230 VAC,
50/60 Hz input
TV0.3-56 0.3 kVA autotransformer; 56 or 115 VAC out for 80 or 160 VDC bus, 115/230
VAC, 50/60 Hz input
TV1.5 1.5 kVA isolation transformer; 115/230 VAC input; 28, 43, 56, 70, 115 VAC output
TV2.5 2.5 kVA isolation transformer; 115/230 VAC input; 28, 43, 56, 70, 115 VAC output
TV5 5 kVA isolation transformer; 115/230 VAC input; 28, 43, 56, 70, 115 VAC output
TB Screw terminal block for BA DB25 control connector
LF AC Line Filter, general noise suppression (not for CE Compliance)
UFM AC Line Filter Module (required for BA amplifiers to meet CE Compliance)